Installation Suggestions for
Acoustiblok on Concrete Screed Floors.

Material checklist:

1. RD350 Acoustiblok roll dispenser (ball bearing rollers allow for easy roll out and height adjustment of up to 2000 lb rolls). Recommended for use with Acoustiblok 60' and 350’ Master size rolls.


2. Staple or nail gun


3. Yellow Grease Pencil


4. Box knives & Straight Edge


5. * Acoustigrip™ tape # AGT60 (180’/roll) and dispenser. Requires approximately 1 roll per 60 linear feet of Acoustiblok.


6. * Acoustiblok Acoustical Sound Sealant # AC10 (10oz tube). Installation requires approximately 2 tubes per 60 linear feet of Acoustiblok. Also available in 29oz tube and 20oz sausage tube sizes.


7. * Acoustiputty™ acoustical sealant pads. Use 1 pad to seal the back of each electrical box or other wall penetrations.


8. Staples (min. 1/2") approximately 200 per 60 linear feet of Acoustiblok. Tin caps # TC5 (1000 tin caps per box). Multiply 0.78 x square footage for total amount needed, or 1 box is enough for 4 - 60' rolls.


Installation Suggestions:


This installation overview provides suggestions for handling and installing Acoustiblok® Sound Isolation Material. Acoustiblok is a heavy, high-density product (1lb/Ft2), so when preparing for the installation, always schedule at least two installers for efficiency and safety.


All tools (except, common hand tools) and materials required for a professional Acoustiblok sound installation are available from Acoustiblok, Inc. See our "Installation Accessories & Hardware Price List" for more details. Use the Acoustiblok RD350 Material Roll Dispenser or similar “A-Frame” type roller stand for safety and ease of handling.


Acoustiblok Sound Isolation Material should always, if possible, be installed on the same side of the assembly as the source of sound or noise. This will decrease the amount of acoustical energy that may be converted into mechanical noise.


It is essential that the treated room be sealed as airtight as possible using Acoustiblok Acoustical Sound Sealant, Acoustigrip Tape, and Acoustiputty sealant pads. The effectiveness of your Acoustiblok sound treatment will be jeopardized if these steps are not taken.


Always install the Acoustiblok Sound Isolation Material with the logo and U.L. printing visible. This allows for quick inspection and sign off from building inspectors and assurance to your clients that they have received an actual Acoustiblok sound reduction treatment, not an inferior, non U.L. rated and acoustically untested product substitution.


For all floor installations it is important to maintain isolation of the underlayments and floor finish with all adjacent surfaces. Always leave a 1/8”-3/8” perimeter gap between the Acoustiwool, Acoustiblok, substrates and flooring from all adjacent wall surfaces. Fill these gaps with Acoustiblok Acoustical Sound Sealant.


Verify that the underlayments and substrates provide the structural requirements of the finished floor.


Confirm the compatability of any adhesives, thinset or other products used with the Acoustiblok products.


Installation of 3mm Acoustiblok1660 3mm on Concrete Slab with 60mm Screed Sub Floor


Clean all surfaces, sweep, wet mop and let dry, to ensure any debris and dust are removed from the area.


Before starting the installation, ascertain which way the Acoustiblok1660 3mm material needs to run i.e.: either length or width ways of the area to be installed, and cut runs of material accordingly.


Ensure the first run of Acoustiblok1660 3mm material is laid square to the starting wall, (remember logo facing upwards), so that the installation will follow this line. Spot glue in place if necessary.


Once the first run of Acoustiblok1660 3mm material is laid, silicone the lead edge and lay the next run of Acoustiblok1660 3mm on top of the silicone edge, abutted to the first run of Acoustiblok1660 3mm. Continue laying each run of Acoustiblok in the same way until the area to be treated has been completely covered.


Leave a 3mm – 10mm perimeter gap between the Acoustiblok1660 3mm, substrate and flooring from all adjacent wall surfaces. Fill perimeter gap with MS Polymer Silicone. The runs of Acoustiblok1660 3mm should be spot glued and particular attention paid to the perimeter edge of the room to ensure a flat and even finish.


Seal all joins of Acoustiblok1660 3mm material with MS Polymer Silicone and Acoustiblok tape. If the Acoustiblok is not lying flat to the floor, allow it to sit overnight at ambient room temperature to allow settlement.


Application with underfloor heating


If underfloor heating is to be fitted to all areas, first ensure silicone is dry and the material has settled, before installing underfloor heating on top of Acoustiblok1660 3mm as per manufacturer’s instructions.


It is recommended that the UF Heating should be floating and therefore no mechanical fixings will penetrate the Acoustiblok membrane. If an adhesive is required it is recommended that the compatibility of the adhesive be verified.


For any further advise on the specification, material or installation, please call our technical team on 01622 840289 who will endeavor to give you comprehensive and practical advice to meet your requirements.



© Acoustiblok UK 2010
Created by www.popi.co.uk
 
                                                                    CALL US ON 01622 840289 OR EMAIL info@acoustiblokuk.com    

Acoustiblok sound proofing product, UK Distributor, Construction product for effective use against sound pollution, anti social noisy neighbours. Thin walls can be sound proofed Acoustic sound blocking system.

Home | 3 MM | 6 MM | About Us | Accessories | All weather external panels | Case Studies | Ceilings | Classroom Acoustics | Commercial | Concrete Screed Floor | Downloads | Floors | Home Cinema | Hospital
Hotels | Hurricane panels | Industrial | Installation | Links | Marine | Masonary Walls | Metal Stud Walls | NBS Plus | Newsletter | Offshore | Residential | RIBA Keyfile | Roads and Railways | Sample |
Sound Transmission and Loss Reports
| Subfloor | Thermablok | Video | Walls | Wood Joist Floor | Wood Stud Walls